{"title":"Leakage Current Tester","description":"","products":[{"product_id":"gw-instek-glc-9000-leakage-current-tester-glc-9000","title":"GW Instek GLC-9000 Leakage Current Tester, 4uA to 25mA, RS-232C, GPIB, USB, EXT-IO, GLC Series","description":"\u003cul\u003e\n\u003cli\u003eTouch Panel with Color LCD Display\u003c\/li\u003e\n\n\u003cli\u003e9 Different Measurement Networks to Simulate the Resistance of Human Body\u003c\/li\u003e\n\n\u003cli\u003e8 Different Types of Leakage current for Medical \u0026amp; General Electrical Equipment\u003c\/li\u003e\n\n\u003cli\u003eLeakage Current Measuring Mode: DC\/AC\/AC+DC\/AC Peak\u003c\/li\u003e\n\n\u003cli\u003eUpper \u0026amp; Lower Limitation for PASS\/FAIL Judgment\u003c\/li\u003e\n\n\u003cli\u003eMeter Mode with SELV\/CONV Function\u003c\/li\u003e\n\n\u003cli\u003e50 Preset Test Conditions Conform to IEC 60990; 30 Sets Memories for Customer Defined Conditions\u003c\/li\u003e\n\n\u003cli\u003eRS-232, GPIB, USB Host \u0026amp; Device\/EXT I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe GLC-9000, leakage current tester, is used to perform leakage current (or called touch current) tests on medical electrical (IEC 60601-1) and general purpose electric \u0026amp; electronic (IEC 60990) equipment. This tester engages with nine measurement networks (also called Measuring Device) to provide the simulation of human body while the device under test is taking a leakage current testing in compliance with the specific standards or regulations such as IEC, UL, JIS, and more.\u003c\/p\u003e\n\n\n\n\u003cp\u003eIn order to provide a simple operation environment, the GLC-9000 has a large TFT LCD touch panel to configure system as well as to present the measurement settings information and result simultaneously. There are 50 preset testing conditions which conform to IEC60990 and other standards In addition, 30 sets empty memory are available for user defined settings.\u003c\/p\u003e\n\n\n\n\u003cp\u003eA Meter mode is also available with the GLC-9000. It uses the measurement terminal (T1\/T2) to measure voltage as the same way of ordinary voltmeter. During the voltage measurement, the SELV function (safety extra low voltage) is applicable to detect whether the voltage value between measuring points exceed the SELV setting.\u003c\/p\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":58407739326796,"sku":"21111.1","price":1918.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/2245\/6652\/files\/instek-glc-9000-front-17020315995.jpg?v=1786712167"},{"product_id":"gw-instek-glc-10000-leakage-current-tester-glc-10000","title":"GW Instek GLC-10000 Leakage Current Tester, 0.01uA to 50mA DC, 7\" TFT LCD Touch Screen, GLC Series","description":"\u003cbody\u003e\n\n     \u003c!-- This is info used by Google but not displayed as text. --\u003e\n        \u003ctitle\u003eGW Instek GLC-10000 Leakage Current Tester\u003c\/title\u003e\n    \n\n\u003cstrong\u003eGW Instek GLC-10000 Leakage Current Tester\u003c\/strong\u003e\n\u003cp\u003eGW Instek launches a new leakage current tester the GLC-10000, which features 12 simulated human impedance networks that comply with related safety regulations so as to conduct leakage current test for electric equipment under normal condition or single fault condition. These 12 simulated human impedance networks are comprised of networks for medical electric equipment and general electric and electronic equipment to ensure that the product design and manufacture are in compliance with requirements of safety regulations including IEC, EN, UL, etc.\u003c\/p\u003e\n\u003cb\u003eFeatures\u003c\/b\u003e\n\u003cul\u003e\n    \u003cli\u003eSuitable for Medical Electrical \u0026amp; General Electrical of Leakage Current Measurement\u003c\/li\u003e\n    \u003cli\u003e7 inch Touch Pane with Color LCD\u003c\/li\u003e\n    \u003cli\u003e12 Different Measurement Network to Simulate the Resistance of Human Body (Including IEC 60601-1:2020 3.2rd)\u003c\/li\u003e\n    \u003cli\u003eThe Measurement of Maximum Allowable Leakage Current is Up to 50mA\u003c\/li\u003e\n    \u003cli\u003eExternal Terminal for Extension MD Connection\u003c\/li\u003e\n    \u003cli\u003eMD OUT Terminal can be Connected to an Oscilloscope for Convenient Comparison of Measured Waveforms\u003c\/li\u003e\n    \u003cli\u003e30 Sets Memories for Test Parameter; 1000 Sets Memories for Measured Data\u003c\/li\u003e\n    \u003cli\u003eTest Parameter Export\/Import Function Through USB Host\u003c\/li\u003e\n    \u003cli\u003eUSB Storage for Measurement Data\/Screen Capture\u003c\/li\u003e\n    \u003cli\u003eVarious Standard Interfaces: RS-232C, USB Host \u0026amp; Device, LAN, Signal I\/O and GPIB (Optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eWhat's in the Box\u003c\/b\u003e\n\u003cul\u003e\n    \u003cli\u003eGLC-10000\u003c\/li\u003e\n    \u003cli\u003ePower cord x 1\u003c\/li\u003e\n    \u003cli\u003eTest lead (GTL-207A) x 2\u003c\/li\u003e\n    \u003cli\u003eCD x 1 (Complete user manual)\u003c\/li\u003e\n    \u003cli\u003eAlligator clips (GLC-01) x 1 (Red x 2\/Black x 2)\u003c\/li\u003e\n    \u003cli\u003eFoil probe (GLC-02) x 1\u003c\/li\u003e\n    \u003cli\u003ePower Cord for EUT (GLC-03) x 1\u003c\/li\u003e\n    \u003cli\u003eInput \u0026amp; output terminal cover (GLC-04) x 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/body\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":58407896318284,"sku":"20000002","price":3023.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/2245\/6652\/files\/GLC-10000_NA_01_042023.jpg?v=1786713671"},{"product_id":"hioki-st5540-leak-current-tester-st5540","title":"Hioki ST5540 Leak Current Tester","description":"\u003cul\u003e\n  \u003cli\u003eIEC 60601-1: (2005) 3rd Edition-compliant\u003c\/li\u003e\n  \u003cli\u003eThe ST5540 complies with JIS, IEC, and UL standards governing medical- and general-use electrical devices\u003c\/li\u003e\n  \u003cli\u003eST5541: A low-cost solution that complies with standards governing general-use electrical devices\u003c\/li\u003e\n  \u003cli\u003eUninterrupted polarity switching function dramatically reduces cycle time\u003c\/li\u003e\n  \u003cli\u003eSupport   for rated currents up to 20 A gives the instrument more than adequate   capability for testing products designed to comply with new standards\u003c\/li\u003e\n  \u003cli\u003eTouch panel features simple, interactive operation\u003c\/li\u003e\n  \u003cli\u003eCommunications functionality and external I\/O support allow automatic testing on production lines\u003c\/li\u003e\n  \u003cli\u003e1-Year warranty \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eA single, Robust Solution for Leak Current Measurement\u003c\/b\u003e\u003cbr\u003e\n\nThe ST5540 and ST5541 feature an improved measuring method and dramatically faster cycle times, thanks to their uninterrupted polarity switching. These new Leak Current Testers support rated currents of up to 20A, making them more than ideal for use with products built to new standards.\u003c\/p\u003e\n\n\u003cb\u003eCompare the ST5540, ST5541 Leak Current Testers\u003c\/b\u003e\u003cbr\u003e\n\u003ctable style=\"display: block; overflow-x: auto; max-width: 100%;\" width=\"100%\" border=\"1\" cellpadding=\"3\" cellspacing=\"0\"\u003e\n\n\u003ctable style=\"display: block; overflow-x: auto; max-width: 100%;\" cellspacing=\"0\" cellpadding=\"3\" border=\"1\"\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003cth colspan=\"2\"\u003eItem\u003c\/th\u003e\n    \u003cth nowrap\u003eST5540\u003c\/th\u003e\n    \u003cth nowrap\u003eST5541\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #fff;\"\u003e\n    \u003ctd rowspan=\"8\" align=\"center\" nowrap\u003eNetwork\u003c\/td\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork A\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork B1\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork B2\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork C\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork D\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork E\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork F\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eNetwork G\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #fff;\"\u003e\n    \u003ctd rowspan=\"12\" align=\"center\" nowrap\u003eTesting leakage current mode\u003c\/td\u003e\n    \u003ctd align=\"center\" nowrap\u003eEarth leakage current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eTouch current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003ePatient auxiliary current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003ePatient leakage current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eTotal patient leakage current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eFree current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eEnclosure - Earth leakage current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eEnclosure - Enclosure leakage current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eEnclosure - Line leakage current\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003ePatient leakage current I\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003ePatient leakage current II\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003ePatient leakage current III\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #fff;\"\u003e\n    \u003ctd rowspan=\"6\" align=\"center\" nowrap\u003eMajor functions\u003c\/td\u003e\n    \u003ctd align=\"center\" nowrap\u003ePower on polarity switching function\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eRated current 20 A\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eFunction for checking for blown fuses\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eFrequency band switching\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003e110% voltage output terminal (T3 terminal)\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd align=\"center\" nowrap\u003eS10, S12, S13, E terminal\u003c\/td\u003e\n    \u003ctd align=\"center\"\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/hioki\/check.gif\" width=\"12\" height=\"16\"\u003e\u003c\/td\u003e\n    \u003ctd align=\"center\" bgcolor=\"#ffffff\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"background-color:#e0edf3;\"\u003eFor applications involving leak current measurement of medical-use electrical devices, use the ST5540.\u003c\/span\u003e \u003cbr\u003eThe ST5540 does not include an isolation transformer (needed for measuring leak current for medical-use electrical devices).\u003c\/p\u003e\n\u003c\/table\u003e","brand":"Hioki","offers":[{"title":"Default Title","offer_id":58407935344972,"sku":"18743.1","price":3916.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/2245\/6652\/files\/5540.jpg?v=1786714090"}],"url":"https:\/\/www.testequity.co.uk\/collections\/leakage-current-tester.oembed","provider":"TestEquity UK","version":"1.0","type":"link"}