{"product_id":"gw-instek-pfr-100l-dc-power-supply-pfr-100l","title":"GW Instek PFR-100L DC Power Supply, Single Output, Fanless, 50V, 10A, 100W, PFR-100 Series","description":"\u003ch5\u003ePFR-100L Programmable and Single Output Fanless Multi-Range DC Power Supply, PFR-100 Series\u003c\/h5\u003e\n\n\u003cul\u003e\n  \u003cli\u003e0 to 50 V, 0 to 10 A, 100 W\u003c\/li\u003e\n  \u003cli\u003eFive-fold rated power multi-range operation\u003c\/li\u003e\n  \u003cli\u003eNatural convection cooling design (fanless structure)\u003c\/li\u003e\n  \u003cli\u003eThree-point memory storage function\u003c\/li\u003e\n  \u003cli\u003eOutput ON\/OFF Delay Function\u003c\/li\u003e\n  \u003cli\u003eCV, CC Priority Mode\u003c\/li\u003e\n  \u003cli\u003eAdjustable Slew Rate For Voltage and Current\u003c\/li\u003e\n  \u003cli\u003eBleeder Circuit Control of up to 31 units\u003c\/li\u003e\n  \u003cli\u003eProtection: OVP, OCP, AC FAIL and OTP\u003c\/li\u003e\n  \u003cli\u003eSupport Front Panel and Rear Panel Output\u003c\/li\u003e\n  \u003cli\u003eStandard USB and RS-232\/485, LAN and GPIB included w\/ PFR-100LGL\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Web Server Monitoring and Remote Control\u003c\/li\u003e\n  \u003cli\u003eExternal Analog Control and Monitor Function\u003c\/li\u003e\n  \u003cli\u003eRemote Sensing Function\u003c\/li\u003e\n  \u003cli\u003eTwo-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The power rating determines the maximum available current for a given voltage output. For example, the PFR-100L is rated at 50 V, 10 A, or 100 W, but you cannot get 50 V and 10 A simultaneously. The maximum current at 50 V is 2 A (50 V x 2 A = 100 W).  Output power cannot exceed V * A.\u003c\/p\u003e\n\n\u003cp\u003eGW Instek's 100-watt PFR-100L is a small high-performance programmable D.C. power supply that adopts natural convection design to dissipate heat. The fanless structure allows you to focus on experiments and tests in a quiet environment. And, the fanless power supply will not suck in dust and foreign objects, contributing to a longer life cycle.\u003c\/p\u003e\n\n\u003cp\u003eThe PFR-100L is a power supply with a five-fold rated power that allows you to define voltage and current under rated power conditions — providing you with wider voltage and current operational ranges. PFR-100L is rated at 100 W. The PFR-100L has a maximum output voltage of 50V (at 2A) or maximum output current of 10A (at 10V).\u003c\/p\u003e\n\n\u003cp\u003eThe PFR-100L provides front and rear panel output terminals. The front panel output terminal helps users shorten test lead replacement time while conducting adjustments on front panel's function keys. The rear panel output terminal facilitates an easy wiring operation for rack mount assembly. Its 70mm width and 2.5 kg in weight have greatly elevated PFR-100 series portability. Furthermore, the multi-drop mode allows you to control up to 31 PFR-100 series power supplies without using switch\/Hub — helping save equipment cost. \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePFR-100 Series Smart Phone Interaction\u003c\/strong\u003e\u003cbr\u003e\nThe LAN interface for PFR-100L is an Ethernet port. It also has a built-in web server and intuitive user interface, allowing monitoring tests via a web browser, tablet or smart phone. In addition, you can remotely adjust PFR-100L settings, including output voltage\/current, the slew rate for voltage\/current, Bleeder circuit control, OCP, delayed time for output voltage and Buzzer settings. The PFR-100L has USB and RS-232\/485 built-in. The PFR-100LGL also includes LAN and GPIB.\u003c\/p\u003e\n\n\u003cp\u003eThe PFR-100L power supply provides special functionalities to meet test requirements for different load characteristics. The CC priority mode can be applied for DUTs with diode characteristics to prevent DUT from being damaged by inrush current. A slow rise time for voltage can also protect DUT from inrush current, especially for tests on capacitive load. When power is off or load is disconnected, the activation of Bleeder circuit control will allow the bleeder resistor to consume filter capacitor's electricity — eliminating a potential hazard. For automatic testing equipment systems, the bleeder resistor allows PFR-100 series to rapidly discharge to prepare itself for the next operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAdjustable Slew Rate\u003c\/strong\u003e\u003cbr\u003e\nThe PFR-100L can adjust slew rate for current and voltage. Via setting the rise and fall time of voltage and current, you can verify DUT's characteristics during voltage and current variation.  Additionally, slew rate adjustment can mitigate voltage shift to effectively prevent DUT from being damaged by inrush current. This function is ideal for tests such as capacitive load and motor.\u003cbr\u003eVoltage slew rate: 0.1V – 100.0V\/sec  |  Current slew rate: 0.01A – 20.00A\/sec\u003c\/p\u003e\n\n\u003cp\u003eThe PFR-100L is well-suited for LED module test and reliability testing, charging tests for battery cell, DC\/DC converter applications, DC motor test applications and solar module quality testing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIn The Box\u003c\/strong\u003e \n\u003c\/p\u003e\u003cul\u003e\n    \u003cli\u003eUser and Programming Manuals on CD\u003c\/li\u003e\n    \u003cli\u003ePower Cord\u003c\/li\u003e\n    \u003cli\u003eGTL-134 and GTL-104A Test Leads\u003c\/li\u003e\n    \u003cli\u003ePFR-001 Accessory Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":58409712386380,"sku":"27255.1","price":732.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/2245\/6652\/files\/PFR-100L-650_1e69b8e8-ecc7-464f-9162-ed146fc2a814.jpg?v=1786719517","url":"https:\/\/www.testequity.co.uk\/products\/gw-instek-pfr-100l-dc-power-supply-pfr-100l","provider":"TestEquity UK","version":"1.0","type":"link"}