{"product_id":"hioki-3153-hipot-insulation-resistance-tester-3153","title":"Hioki 3153 Hipot \/ Insulation Resistance Tester","description":"\u003cp\u003e\u003cb\u003eHipot \/ Insulation Resistance Tester\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eInsulation and AC\/DC continuous voltage withstand testing \u003c\/li\u003e\n  \u003cli\u003e0.2 kV to 5.00 kV AC, 500 VA\u003c\/li\u003e\n  \u003cli\u003e0.2 kV to 5.00 kV DC, 50 VA\u003c\/li\u003e\n  \u003cli\u003eSafety standards compliance testing \u003c\/li\u003e\n  \u003cli\u003eStores up to 10 sets of test conditions (10 each for insulation and voltage withstand) \u003c\/li\u003e\n  \u003cli\u003eZero-V Switching (voltage withstand testing) \u003c\/li\u003e\n  \u003cli\u003eElectrical Discharge function (DC voltage withstand, insulation testing) \u003c\/li\u003e\n  \u003cli\u003eAutomated testing support \u003c\/li\u003e\n  \u003cli\u003eInterlock Protect function \u003c\/li\u003e\n  \u003cli\u003eRemote controllable\u003c\/li\u003e\n  \u003cli\u003e1-Year Warranty \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eProgrammable testing, full remote control, Automatic Insulation Withstanding Tester \u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis electrical safety test instrument series is designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and labor-saving features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications. \u003c\/p\u003e\n\n\u003cstrong\u003eBasic Specifications:\u003c\/strong\u003e Withstanding test section\u003cbr\u003e\n\u003ctable style=\"display: block; overflow-x: auto; max-width: 100%;\" width=\"100%\" border=\"1\" cellpadding=\"3\" cellspacing=\"0\"\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd width=\"150\"\u003eTesting voltage\u003c\/td\u003e\n    \u003ctd\u003e0.2 kV to 5.00 kV AC, 500VA (maximum 30 minutes)\u003cbr\u003e\n      0.2 kV to 5.00 kV DC, 50VA (continuous)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eVoltage setting method\u003c\/td\u003e\n    \u003ctd\u003eDigital setting\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eWaveform\u003c\/td\u003e\n    \u003ctd\u003eSame as the power supply waveform\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eFrequency\u003c\/td\u003e\n    \u003ctd\u003eSame as the power supply frequency\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eMeasurement range\u003c\/td\u003e\n    \u003ctd\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0.01 to 100.0 mA, ±(2 % f.s. +5 dgt.) 10 mA\/100 mA AC (Average value rectified, effective value display)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cstrong\u003e\u003cbr\u003e\nBasic Specifications:\u003c\/strong\u003e Insulation test section\u003cbr\u003e\n\u003ctable style=\"display: block; overflow-x: auto; max-width: 100%;\" width=\"100%\" border=\"1\" cellpadding=\"3\" cellspacing=\"0\"\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd width=\"150\"\u003eTesting voltage\u003c\/td\u003e\n    \u003ctd\u003e50 V to 1000 V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eMeasurement range\u003c\/td\u003e\n    \u003ctd\u003e0.1 m-ohm to 9999 m-ohm, 4 ranges\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cstrong\u003eBasic specifications:\u003c\/strong\u003e General\u003cbr\u003e\n\u003ctable style=\"display: block; overflow-x: auto; max-width: 100%;\" width=\"100%\" border=\"1\" cellpadding=\"3\" cellspacing=\"0\"\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd width=\"150\"\u003eJudgment function\u003c\/td\u003e\n    \u003ctd\u003e\n\u003cstrong\u003eContents:\u003c\/strong\u003e UPPER-FAIL \/ PASS \/ LOWER-FAIL (Digital setting window comparator method)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eTimer section\u003c\/td\u003e\n    \u003ctd\u003e\n\u003cstrong\u003eSetting range:\u003c\/strong\u003e 0.3 to 999 seconds\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eInterfaces\u003c\/td\u003e\n    \u003ctd\u003eEXT I\/O, EXT SW, RS-232C, GPIB\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eDisplay\u003c\/td\u003e\n    \u003ctd\u003eVacuum Fluorescent display (digital), Analog meter\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003eMonitor function\u003c\/td\u003e\n    \u003ctd\u003eOutput voltage, detection current\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr valign=\"top\"\u003e\n    \u003ctd\u003ePower supply\u003c\/td\u003e\n    \u003ctd\u003e100 V to 120 V AC \/ 200 to240 V AC, (50\/60 Hz), 1000 VA max.\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Hioki","offers":[{"title":"Default Title","offer_id":58407960248652,"sku":"18499.1","price":5153.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/2245\/6652\/files\/3153-300.jpg?v=1786714364","url":"https:\/\/www.testequity.co.uk\/products\/hioki-3153-hipot-insulation-resistance-tester-3153","provider":"TestEquity UK","version":"1.0","type":"link"}