{"product_id":"keithley-2604b-20866-1","title":"Keithley 2604B Dual Channel SourceMeter, 40 V, 3 A DC, 10 A Pulse","description":"\u003cp\u003eModel 2604B is intended for benchtop applications and does not include not include TSP-Link, Contact Check, or Digital I\/O capabilities.\u003c\/p\u003e \n\u003cul\u003e\n  \u003cli\u003eDual Channel \u003c\/li\u003e\n  \u003cli\u003eMax Current Source\/Measure Range: 10A (3 A DC, 10 A Pulse)\u003c\/li\u003e\n  \u003cli\u003eMax Voltage Source\/Measure Range: 40V\u003c\/li\u003e\n  \u003cli\u003eMeasurement Resolution:  100fA \/ 100nV\u003c\/li\u003e\n  \u003cli\u003eTightly integrated, 4-quadrant voltage\/current source and measure instruments offer best in class performance with 6-1\/2-digit resolution \u003c\/li\u003e\n  \u003cli\u003eBuilt-in web browser based software enables remote control through any browser, on any computer, from anywhere in the world \u003c\/li\u003e\n  \u003cli\u003eCompatibility with the Keithley IVy mobile app enables true plug \u0026amp; play I\/V characterization and test through any Android device \u003c\/li\u003e\n  \u003cli\u003eSoftware emulation for Keithley 2400 SourceMeter SMU Instrument\u003c\/li\u003e\n  \u003cli\u003eUSB 2.0, LXI-C, GPIB, and RS-232\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eKeithley Series 2600B SourceMeter SMU Instruments are the industry's leading current\/voltage source and measure solutions, and are built from Keithley's third generation SMU technology. The Series 2600B offers single- and dual-channel models that combine the capabilities of a precision power supply, true current source, 6-1\/2-digit DMM, arbitrary waveform generator, pulse generator, and electronic load – all into one tightly integrated instrument. The result is a powerful solution that significantly boosts productivity in applications ranging from bench-top I-V characterization through highly automated production test. \u003c\/p\u003e\n\n\u003cp\u003eBuilt-in web browser based software enables I-V testing through any computer from anywhere in the world. Or, use your Android smart device to perform plug \u0026amp; play I-V testing with fingertip control with the Keithley IVy application. Because Series 2600B SourceMeter SMU Instruments have fully isolated channels that do not require a mainframe, they can be easily reconfigured and re-deployed as your test applications evolve.\u003c\/p\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel\u003c\/th\u003e\n      \u003cth\u003eChannels\u003c\/th\u003e\n      \u003cth\u003eMax Current \u003cbr\u003e\n      DC \/ Pulse \u003c\/th\u003e\n      \u003cth\u003eMax \u003cbr\u003e\n      Voltage\u003c\/th\u003e\n      \u003cth\u003eMeasurement\u003cbr\u003e\n      Resolution \u003c\/th\u003e\n      \u003cth\u003ePower*\u003c\/th\u003e\n      \u003cth\u003eVersion**\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2601B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n      \u003ctd\u003e3A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e40V\u003c\/td\u003e\n      \u003ctd\u003e100fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e40.4 W\u003c\/td\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2602B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e2\u003c\/td\u003e\n      \u003ctd\u003e3A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e40V\u003c\/td\u003e\n      \u003ctd\u003e100fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e40.4 W\u003c\/td\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2604B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e2\u003c\/td\u003e\n      \u003ctd\u003e3A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e40V\u003c\/td\u003e\n      \u003ctd\u003e100fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e40.4 W\u003c\/td\u003e\n      \u003ctd\u003eBenchtop\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2611B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n      \u003ctd\u003e1.5A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e200V\u003c\/td\u003e\n      \u003ctd\u003e100fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e30.3 W\u003c\/td\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2612B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e2\u003c\/td\u003e\n      \u003ctd\u003e1.5A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e200V\u003c\/td\u003e\n      \u003ctd\u003e100fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e30.3 W\u003c\/td\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2614B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e2\u003c\/td\u003e\n      \u003ctd\u003e1.5A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e200V\u003c\/td\u003e\n      \u003ctd\u003e100fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e30.3 W\u003c\/td\u003e\n      \u003ctd\u003eBenchtop\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2635B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n      \u003ctd\u003e1.5A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e200V\u003c\/td\u003e\n      \u003ctd\u003e0.1fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e30.3 W\u003c\/td\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2634B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e2\u003c\/td\u003e\n      \u003ctd\u003e1.5A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e200V\u003c\/td\u003e\n      \u003ctd\u003e1fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e30.3 W\u003c\/td\u003e\n      \u003ctd\u003eBenchtop\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2636B\u003c\/td\u003e\n      \u003ctd align=\"center\"\u003e2\u003c\/td\u003e\n      \u003ctd\u003e1.5A \/ 10A\u003c\/td\u003e\n      \u003ctd\u003e200V\u003c\/td\u003e\n      \u003ctd\u003e0.1fA \/ 100nV\u003c\/td\u003e\n      \u003ctd\u003e30.3 W\u003c\/td\u003e\n      \u003ctd\u003e \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cbr\u003e\n\u003cp\u003e*Max. DC Power per Channel \u003cbr\u003e\n**Benchtop versions do not include TSP-Link, Contact Check, or Digital I\/O capabilities.\u003c\/p\u003e","brand":"Keithley","offers":[{"title":"Default Title","offer_id":58361166725452,"sku":"20866.1","price":12300.0,"currency_code":"GBP","in_stock":false}],"url":"https:\/\/www.testequity.co.uk\/products\/keithley-2604b-20866-1","provider":"TestEquity UK","version":"1.0","type":"link"}