{"product_id":"keysight-3458a-digital-bench-multimeter-trms-1000-v-1-a-cat-iii-600v-8-5-digit-3458a","title":"Keysight 3458A Digital Bench Multimeter, TRMS, 1000 V, 1 A, CAT III 600V, 8.5 Digit","description":"\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e8 1\/2 Digits\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMeasure with confidence with up to 8 ppm 1-year DCV accuracy (4ppm with option 002)\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMaximize productivity with fast measurement speeds up to 100K readings\/s\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eUp to 148K reading memory for prolonged data logging (extended memory now included in all new 3458A effective 10\/2019)\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eDCV and ACV, DCI and ACI, Frequency, Temperature\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e2- and 4-wire Resistance\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMaximum sensitivity: 10 nV\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eProgrammable integration times from 500 ns to 1 sec\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eTwo-source (10 V, 10 kΩ) calibration, including AC\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eSelf-adjusting, self-verifying auto-calibration for all functions and ranges, including AC\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMultimeter Language (ML) compatible\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eGPIB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eKeysight 3458A Multimeter, recognized the world over as the standard in high performance DMMs, offers very high accuracy and high-speed digitizing for calibration laboratory precision measurements and fast test system throughput.\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eSelect a reading rate of 100,000 readings per second for maximal test throughput. Or achieve highest levels of precision with up to 8-1\/2 digits of measurement resolution and 0.1 part per million transfer accuracy. Add this to the Keysight 3458A's simplicity of operation, and you have the ideal multimeter for your most demanding applications.\u003c\/p\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr valign=\"top\"\u003e\n\u003ctd\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDC Volts\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e5 ranges: 0.1 V to 1000 V\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e8-1\/2 to 4-1\/2 digits resolution\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eUp to 100,000 readings\/s (4-1\/2 digits)\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMaximum sensitivity 10 nV\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e0.6 ppm 24-hour accuracy\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e8 ppm)\/year voltage reference stability (4 ppm with opt. 002\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eResistance\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e9 ranges: 10 ohms to 1 Gohms\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e2-wire and 4-wire measurements with offset compensation\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eUp to 50,000 readings\/second (5-1\/2 digits)\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMaximum sensitivity 10 micro-ohms\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e2.2 ppm 24-hour accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eAC Volts\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e6 ranges: 10 mV to 1000 V\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e1 Hz to 10 MHz bandwidth\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eUp to 50 readings\/s with all readings to specified accuracy\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eChoice of sampling or analog true rms techniques\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e100 ppm best accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDC Current\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e8 ranges: 100 nA to 1 A\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eUp to 1,350 readings\/s (5-1\/2 digits)\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMaximum sensitivity 1 pA\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e14 ppm 24-hour accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eAC Current\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e5 ranges: 100 µA to 1 A\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e10 Hz to 100 kHz bandwidth\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eUp to 50 readings\/second\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e500 ppm 24-hour accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eFrequency and Period\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eVoltage or current ranges\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eFrequency: 1 Hz to 10 MHz\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003ePeriod: 100 ns to 1 second\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e0.01% accuracy\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eAC or DC coupled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eFeatures\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eMath and Statistics\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e20 kB memory\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eSelf-adjusting autocalibration\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eUp to 100,000 readings\/s over GPIB or with internal memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eIncludes operation and service manuals, test lead set, power cord, NIST-traceable calibration certificate. Three-year warranty.\u003c\/p\u003e","brand":"Keysight","offers":[{"title":"Default Title","offer_id":58411342332236,"sku":"14738.5","price":12599.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/2245\/6652\/files\/3458A-500.jpg?v=1786723885","url":"https:\/\/www.testequity.co.uk\/products\/keysight-3458a-digital-bench-multimeter-trms-1000-v-1-a-cat-iii-600v-8-5-digit-3458a","provider":"TestEquity UK","version":"1.0","type":"link"}