TestEquity UK
Keithley
Keithley

Keithley DAQ6510 Data Acquisition Mainframe, Multimeter, 2 Module Slots, 80 Channel, DAQ6500 Series

Part #25894.1

MFG #DAQ6510

Keithley DAQ6510
Keithley
Keithley

Keithley DAQ6510 Data Acquisition Mainframe, Multimeter, 2 Module Slots, 80 Channel, DAQ6500 Series

Part #25894.1

MFG #DAQ6510

£
£

Data Acquisition and Logging, Multimeter System

Features

  • Large, 5-inch (12.7 cm) multi-touch capacitive touchscreen with graphical display
  • 2-year specified, full featured, traceable 6-1/2 digit multimeter with 0.0025% DCV (1 V, 10 V ranges) basic accuracy
  • Standard LAN/LXI and USB-TMC communication interfaces
  • Optional interfaces include GPIB, RS-232, and TSP-Link® Technology
  • 12 different switch, RF, and control modules to connect to as many as 80 DUTs in one test setup
  • Up to 80 2-pole channels of thermocouple, RTD, or thermistor temperature measurements
  • Scanning speeds as high as 800 channels/second with the solid state relay module
  • Front panel jacks for stand-alone DMM operation
  • KickStart coding-free instrument control software with a data acquisition and logging application
  • Three-year warranty

NOTE: Plug-in Modules sold separately.

The DAQ6510 is a precision data acquisition and logging system that creates a new level of simplicity compared with the often complicated configuration and control found in many stand-alone solutions. A large 5-inch (12.7 cm) multi-touch display will guide users through set-up, data visualization, and analysis, removing the necessity of a PC and custom software for many applications. If you prefer or require a PC, a complement of IVI and Labview drivers and the Keithley KickStart Instrument Control Software are available to help with any application.

Using Keithley’s newest 6½-digit multimeter technology, you will find even greater accuracy, functionality, and speed. Two-year accuracy specifications are included, so you can be assured your critical measurements remain accurate and fully traceable.

With 12 plug-in switching and control modules available and two module slots, you can build a test system that can measure or control up to 80 devices-under-test (DUTs) in a multiplexing configuration. With two 6×8 matrix modules, a total of 96 crosspoints, the DAQ6510 can test one or multiple ICs. For high volume production testing, select a solid-state multiplexer module to maximize throughput with 800 channels/s scanning speed and minimize downtime compared with a fixed life, electromechanical relays. A number of modules have cold junction compensation, temperature references for thermocouple temperature monitoring of devices during environmental testing, and HALT and HASS accelerated life testing. Even switch signals from wireless devices with RF modules having a maximum switching frequency of 3.5 GHz.

Optional Series 7700 Plug-in Switch Modules
Model Description Analog
Channel
Configuration Max.
Voltage
Max. Switched Current Bandwidth
7700 20-Channel DIfferential Multiplexer Module
with Automatic CJC
20 Multiplexer w/CJC
1x20 or two 1x10
300 V 1 A 50 MHz
7701 32-Channel Differential Multiplexer Module 32 Multiplexer
1x32 or two 1x16
150 V 1 A 2 MHz
7702 40-Channel Differential Multiplexer Module 40 Multiplexer
1x40 or two 1x20
300 V 1 A 2 MHz
7703 32-Channel, High Speed, Differential
Multiplexer Module
32 Multiplexer
1x32 or two 1x16
300 V 500 mA 2 MHz
7705 40-Channel Single-Pole Control Module 40 Independent SPST
300 V 2 A 10 MHz
7706 All-in-One I/O Module 20 Mutiplexer w/CJC
1x20 or two 1x10
300 V 1 A 2 MHz
7707 32-Channel Digital I/O Module 10 Digital I/O Multiplexer
1x10 or two 1x5
300 V 1 A 2 MHz
7708 40-Channel Differential Multiplexer Module with Automatic CJC 40 Multiplexer w/CJC
1x40 or two 1x20
300 V 1 A 2 MHz
7709 2 pole, 6x8 Matrix Module 48 Matrix
6x8
300 V 1 A 2 MHz
7710 20-Channel Solid State Differential
Multiplexer with Automatic CJC
20 Multiplexer w/CJC
1x20 or two 1x10
60 V 0.1 A 2 MHz

Maximize the Range of Tests with an Extensive Array of Plug-In Switch Modules
Build a DAQ6510 test system with a selection of 12 plug-in switch modules with a wide range of functionality. Select from high-density, 40-channel multiplexer modules, a 6x8 matrix module, and multiplexer modules with digital I/O and analog output. Also select a control module and two RF modules with 2 GHz and 3.5 GHz bandwidths. Thus, the DAQ6510 with its 12 switch modules provides an extensive range of flexibility to build a wide range of data acquisition or test systems.

Channels can be configured for any DMM measurement. For example, measure the temperature of devices in an environmental chamber with thermocouples using the plug-in switch modules that have automatic cold reference junction compensation for thermocouple measurements. Measure up to 80 devices with two switch modules. Also measure other parameters in addition to temperature.

Visualize, Execute, and Debug Your Test Setup in Minutes
Build a test sequence and define the required measurements from one setup screen. First, select the channels that will be used. Next, assign a measurement function to a channel or a group of channels. Then define both the time interval between measurements and scans if multiple scans are required. That is the minimum set of parameters needed to run a test. There are additional optional parameters to adjust the measurements and the switching to meet a specific application. One option eases the identification of channels by allowing the creation of a name for each channel. Do all this from two menus and see — on one screen — how each channel is configured. The touchscreen, graphic display shows the channel setup and the measurement programmed for each channel.

Save Valuable Time with Continuous Monitoring of Scan Test Status
Never lose time with a test in which a problem such as a broken wire, a mis-wired connection, or a defective DUT can invalidate days of data. Use the scan status, swipe screen to continuously monitor channels. The status screen shows the percentage of the test that has been completed, the number of scans that have been completed, measurements on channels selected for monitoring, and whether any measurements are out of range.

Monitor Any Temperature Range and Select Optimal Accuracy Using a Wide Range of Temperature Sensors
The DAQ6510 can process signals from any of eight thermocouple types to test over an extreme range of temperatures, -200°C to 1820°C. For more accurate temperature readings over a more narrow temperature range, the DAQ6510 can measure temperature from -80°C to 150°C with a 2-year accuracy of 0.08°C using 2.5 kΩ, 5 kΩ, and 10 kΩ thermistors. Alternatively, the DAQ6510 can measure temperature between -200°C and 850°C using resistance temperature detectors (RTDs) with 2-wire, 3-wire, and 4-wire configurations. Using a 4-wire RTD, temperature can be measured with with an excellent 2-year accuracy of 0.06°C.

Data Logging Software Simplifies PC Control, Acquisition, and Analysis
KickStart allows you to configure, test, and collect data from multiple instruments, including DMMs, power supplies, SMU instruments, and dataloggers. You can control up to eight instruments at the same time and retrieve millions of readings from each instrument. This makes KickStart a great solution for your datalogging needs and for capturing lots of data from transient events with a digitizing DMM.

Wide Range of PC Interfaces
You can choose the interface that is most suitable for your needs. Two PC interfaces, LAN LXI and USB, on the DAQ6510 are standard. In addition, field-installable interface options include a GPIB interface, an RS-232 interface, and the Keithley TSP-Link interface. All these options include six digital I/O ports for direct instrument-instrument synchronization and communication.

In The Box

  • Data Acquisition And Multimeter System
  • 1756 General Purpose Test Lead Set, 1000 V, CAT II x 2
  • USB-B-1 USB Cable, Type A to Type B, 1m (3.3 ft)
  • Traceable Calibration Certificate
  • Three-Year Warranty
  • Instruction Manuals and Documentation available to download

Brand: Keithley
Series: DAQ6500 Series
Display: TFT LED
Display Digits: 6.5
Display Type: 5 Capacitive Touch
Input Voltage: 100/240 VAC
Interface: LAN/LXI and USB
Maximum Current: 3 A
Maximum Voltage: 1000 V
Memory: 7 million readings
Mounting Type: Bench Top
Number of Channels: 80 Channel
Quote Required: No
Sampling Rate: 1 MS/s
UK SKU #: N|TEK|16536
Video: 1092030
Warranty: 3 Years
£
£